Products


Steel Wedge Gate Valves With Nonrising Stem

Destination:

The wedge gate valves are used for a complete or partial shutting-off of a fluid flow as well as for resuming the initial flow of the same fluid, for nominal pressures of 140, 210, 350 bar (2000, 3000, 5000 PSI) .
Working medium: water, gases, petroleum products and other similar fluids with a light corrosive action.

Contents

1. Body
2. Cover
3. Stem
4. Stud
5. Nut
6. Gasket
7. Gate
8. Sealing rings
9. Gasket
10. Hand wheel

Technical and constructive characteristics

PN
(PSI)

DN
(in)

d1
(mm)

d2
(mm)

n x d3

H
(mm)

d4
(mm)

L
(mm)

b
(mm)

D
(mm)

Weight

2000
2 1/16
165
127
8 x 18
400
82,5
295
33,3
250
48
2 9/16
190
149,2
8 x 22
440
101,6
333
36,5
320
74
3 1/8
210
168,5
8 x 22
460
123,8
359
39,7
320
82
4 1/16
275
215,9
8 x 26
515
149,2
435
46
360
161
3000
2 1/16
215
165,1
8 x 26
460
95,2
371
46,1
320
92
2 9/16
245
190,5
8 x 28
520
107,9
422
49,2
320
105
3 1/8
240
190,5
8 x 26
480
123,8
435
46,1
360
125
4 1/16
295
235
8 x 32
540
149,2
511
52,4
450
190
5000
2 1/16
215
165,1
8 x 26
480
95,2
371
46,1
320
101
2 9/16
245
190,5
8 x 30
530
107,9
422
49,3
320
108
3 1/8
270
203,2
8 X 33
570
136,5
473
55,6
360
169
4 1/16
310
241,3
8 X 36
700
161,9
549
62
500
205

Operating and constructive characteristics

Designed in accordance with API specification 6A requirements.
The products are designed to perform according to the requirements of PR1 Performance Requirement Level and, on request, PSL1, PSL2 and PSL3 Product Specification Levels.
About Material class and Temperature classification, see Appendix A.
Body shape – straight, with round top flange.
Closing element – monoblock wedge gate.
Sealing of the passing section on the seat: 17%Cr/17%Cr or simple metal-to-metal.
Acting stem: nonrising, rotating, threaded.
The valve is connected to the pipe by flanges provided with sealing metallic rings.
Mounting position: indifferent
Acting: by turning of handwheel
The valve is connected to the pipe by flanges provided with “R” type sealing metallic rings.

Working and testing regime

Nominal pressure
PSI
Working pressure
PSI
Testing pressure
PSI
120oC Strength Tightness
2000 2000 4000 2000
3000 3000 6000 3000
5000 5000 10000 5000