Products


Equipments

Destination:

To obtain some technical performances (pressure, output), the Cementing Units can be equiped with one of aforementioned equipments without reducing the volumetric efficiency of triplex plunger pump.
The equipment is mounted in a liner able for each type and dimensions of plunger.
The liner seales against hydraulic body with a “U” gasket and an “O” ring.
The liner is fixed with a threaded sleeve which is common for the entire range of liners.
The sealing pack (high and low pressure pack) is adjusted with the stuffing box cover by means of the pressing bushing. The stuffing box cover is common for the entire range of plungers.
The plungers are tubular shaped and are hard chromium plated on the exterior.
They are fastened by means of extension rod and a nut.

Contents

1. Liner IC45 / SR EN 10083 forged
2. Gasket rubber
3. Sealing pack subassy
4. Stuffing box bushing subassy
5. “O”-ring rubber
6. Plunger IC45 / SR EN 10083

Technical and constructive characteristics

Equipment size

Ø85 mm

Ø90 mm

Ø100 mm

Ø115 mm

Ø125 mm

Max. working press, bar

1050

500

500

400

400

700

300

300

530

250

450

Max. theoretical outout, l/min

1020

717

1044

885

1290

1411

1170

1705

1866

2010

2205

Liner dimens., mm

Ø85x 310

Ø90x 240

Ø90x 240

Ø100x 240

Ø100x 240

Ø100x 310

Ø115x 240

Ø115x 240

Ø115x 310

Ø125x 240

Ø125x 320

Equiped Unit

ACF 1050

AC 500A

AC 500B

AC 400 si 500A

AC 500B

ACF 700 si 1050

AC 400 si 500A

AC 500B

ACF 700 si 1050

AC 500B

ACF 700 si 1050